Frequency range                               

9kHz~9GHz/20GHz                  

Display average noise level (1 GHz)

 ≤-163dBm/Hz (typical)


Technical Specifications            |             Product Overview         


Technical Specifications


Model

4042B/D

Frequency Range

4042B: 9 kHz ~ 9 GHz;

4042D: 9 kHz ~ 20 GHz

Frequency Reference

Nominal frequency:  10 MHz

Aging rate:     ±  5×10 -7 /year

Initial frequency accuracies:  ±  3×10 -7

Temperature stability:  ± 1×10 -7  ( 0  ℃  ~   +  5 0 ℃ , relative to  2 5  ℃ ± 10 ℃ )

Frequency reference errors:   ± (To last calibration date × Aging rate + Temperature stability + Calibration accuracy)

Note: Default to the last calibration time is 1year, this indicator is guaranteed by the crystal manufacturer.

Scanning Time

Range:          1 μs ~ 6000 s (zero-scan width)

Accuracy:     ±1.0% (zero-scan width)

Frequency Readout Accuracy

± (Frequency reading × Frequency reference errors + 1% × sweep width + 10% × Resolution bandwidth)

Sweep Width

Range:         0 Hz (zero-scan width), 10 Hz ~ Frequency range upper limit

Accuracy:   ± 1.0 %

Resolution Bandwidth

Bandwidth range:  1 Hz ~ 20 MHz(with 1-2-3-5-8 Step)

Video Bandwidth

Bandwidth range:  1 Hz ~ 20 MHz(with 1-2-3-5-8 Step)

Sideband Noise

(Carrier wave  1 GHz ,  +  15  ℃   +  35  ℃)

 ≤ -108 dBc/Hz@10 kHz,  ≤ -110 dBc/Hz@100 kHz

 ≤ -118 dBc/Hz@1 MHz,  ≤ -129 dBc/Hz@10 MHz

Display Average Noise Level

(Input port connects with 50 Ω  load, 0 dBinput Attenuation, mean value detection.
Resolution bandwidth normalization to 
1 Hz ,  +  15  ℃  +  35  ℃)

Pre-amplifier on:

 ≤ -161 dBm (2 MHz ~ 2.4 GHz),  ≤ -160 dBm (2.4 GHz ~ 6 GHz),

 ≤ -159 dBm (6 GHz ~ 9 GHz),   ≤  -158 dBm (9 GHz ~ 14 GHz),

 ≤ -156 dBm (14 GHz ~ 20 GHz)

Pre-amplifier off:

 ≤ -142 dBm (2 MHz ~ 2.4 GHz),  ≤ -141 dBm (2.4 GHz ~ 6 GHz),

 ≤ -140 dBm (6 GHz ~ 9 GHz),   ≤ -138 dBm (9 GHz ~ 14 GHz),

 ≤ -138 dBm (14 GHz ~ 20 GHz)

Second Harmonic Distortion

(Attenuation  0 dB,-30 dBm input ,
Pre-amplifier off
)

 ≤ -70 dBc (50 MHz ~ 10 GHz)

Third-order Sympathetic Distortion

( -15 dBmtwo-tone signal,100 kHzintervals, 0 dBAttenuation, Pre-amplifier off)

≥ + 13 dBm (50 MHz ~ 20 GHz)

Mirroring, Multiple and Out-of-Band Response

( -10 dBm mixer level)

<-65 dBc ( 10 MHz ~ 7.5 GHz ),  < -60 dBc ( 7.5 GHz ~ 10.5 GHz ),

<-65 dBc ( 10.5 GHz ~ 20 GHz )

Residual Response

(RF Input port connects with 50 Ω  load,0 dB inputAttenuation )

Pre-amplifier on:

 ≤ -110 dBm (10 MHz ~ 3 GHz), ≤ -105 dBm (3 GHz ~ 9 GHz)

 ≤ -103 dBm (9 GHz ~ 12 GHz), ≤ -100 dBm (12 GHz ~ 20 GHz)

Pre-amplifier off:  ≤ -90 dBm (10 MHz ~ 20 GHz)

Total Level Uncertainty

(Frequency 10 MHz ~ 20 GHz,
Attenuation 10 dB,0 dBm ~ -50 dBm,
Pre-amplifier off,
Resolution bandwidth1 kHz,
other parameters are automatically)

±1.30  dB (Working temperature + 15 ℃ ~  + 35 ℃)

 Input Attenuation

Attenuation Range:  0 ~ 30 dB, 2 dB Step

Maximum Safe Input Levels

 +  27 dBm,  CW

(  Input frequency ≥ 50 MHz,  ≥ 10 dB Attenuation  , Pre-amplifier off )

Reference levels

Range:  -150 dBm ~  + 30 dBm, Min: 1 dB Step

Conversion errors:  ± 0.50 dB (Reference levels 0 dBm ~ -60 dBm)

Detection Mode

Standard, Positive Peak, Negative Peak, Sampling, Mean, Root Mean Square

Size

377  mm(W) × 2 50  mm(H)× 119.5  mm(D)

( Closed feet without protrusions such as carrying handles, rotary pulse generators, adapters, etc. )

Weight

 ≤ 6.5 kg

Working Temperature

 0 ℃ ~  + 50 ℃

Storage Temperature

 -40 ℃ ~  + 70 ℃

Electromagnetic Compatibility (EMC)

Conforms to GJB 3947A-2009, item 3.9.1.

Power Supply

100 ~ 120 V AC 50 ~ 60 Hz; or 200 ~ 240 V AC 50 ~ 60 Hz

Power Consumption

 ≤ 55 W

Test Ports

RF  input:  N port  female

Other Ports

10 MHz reference input/output:  BNC female

External trigger input interface:  BNC female

GPS antenna interface:                SMA female (Optional, reserved)

IF Output Interface:                      BNC female (Optional)

Wi-Fiantenna interface:               SMAFemale(Optional, reserved)

Communication and Auxiliary Interfaces

Front panel:  1 USB3.0 Type A port, 1 USB2.0 Type A port

Back panel:  2 USB2.0 Type A ports, 1 USB3.0 Type B port (reserved), 1 USB2.0 Type C port

LAN port:    Standard RJ-45 type, 1 HDMI port

 


Product Overview


Ceyear 4042 series spectrum analyzer is the new basic spectrum analyzer launched by Ceyear, the frequency measurement range covers 9kHz~20GHz. 4042 series spectrum analyzer adopts portable structure, the weight is less than 6.5kg, with the advantages of wide working frequency band, high performance index, fast scanning speed, multi-functions, portable and easy to operate, and other multiple advantages.


    4042 series spectrum analyzer has real-time spectrum analysis, interference analysis, channel scanning, field strength measurement, USB continuous wave and peak power measurement, analog demodulation analysis, IQ analysis and other measurement function modes, as well as channel power, occupancy bandwidth, neighboring channel power, spectrum emission templates, carrier-to-noise ratio, harmonic distortion, spurious emission templates, and other intelligent measurement functions, support LAN, USB, HDMI and other digital interfaces. 4042 adopts 12.1-inch multi-touch capacitive touch screen to bring a better interactive experience, the product can be applied to industrial electronic product development and testing process as well as communications testing, satellite communications, microwave communications, scientific research and teaching and many other fields.


Main Features

Frequency measurement range:               9 kHz ~ 9 GHz/20 GHz, with full-band preamplifier as standard;


RF performance indicators

Display average noise level:                        ≤ -163 dBm/Hz (10 MHz ~ 2 GHz, preamplifier on, typical value)

Single-sideband phase noise:                     ≤ -113 dBc/Hz@100 kHz frequency offset@1 GHz carrier (typical value)

                           ≤ -108 dBc/Hz@100 kHz frequency offset@10 GHz carrier (typical)

Third order intermodulation distortion:   + 16 dBm@900 MHz (typical)

Total level uncertainty:                                 ±1.0 dB (typical)

Fast sweep speed:                                         Sweep time < 33 ms (sweep width 20 GHz, resolution bandwidth 3 MHz)

                                                                          Scan time < 4 s (sweep width 1 GHz, resolution bandwidth 1 kHz, fast FFT scan mode)


Multiple measurement function modes: spectrum analysis, interference analysis (waterfall plot, RSSI), channel scanning, field strength measurement, USB continuous wave power measurement, USB peak power measurement, analog demodulation analysis (AM, FM, PM), real-time spectrum analysis (maximum analysis bandwidth of 40 MHz), IQ analysis, and time-gate scanning;

A variety of intelligent measurement functions: channel power, occupied bandwidth, neighboring channel power, spectrum emission templates, carrier-to-noise ratio, harmonic distortion, spurious emission templates and so on;

Various auxiliary test interfaces and digital interfaces: 10 MHz reference input and output, zero-sweep IF output, LAN, USB, HDMI, etc;

Convenient user operation experience: 12.1-inch capacitive touch screen, support for multi-touch, with 6 independent markers, support for signal tracking and peak tracking, with 3 display traces, 6 types of detection methods (standard, positive peak, negative peak, sampling, average, root mean square), support for HDMI output;

Support a variety of external options and accessories, such as USB continuous wave power probe, USB peak power probe, EMI near-field probe.