RF Measurement

Concerning RF measurements we can offer: scattering parameter measurement, near- and far- field measurement. For the measurement of the field distributions we have xyz and azimuthal positionier. We may also built a positioning system for your needs.


Furthermore, we have a GTEM cell working up to 6 GHz and several TEM cells for different frequecy ranges and testing volumes. Again, we can build  a tailored TEM cell for your requirements (conventional stripline with two ground planes or a more open microstrip line). Just contact us!



Scattering Parameter Measurement

We can carry out scattering parameter measurements with our 4-port ZVA for you. We can connect the VNA directly to coaxial connector based devices or use on-wafer probes instead.

On-chip measurement using waveguide based probe (on the right), coaxial based probe (lower left) and some DC lines for biasing (in the back).


EMI Measurements with GTEM Cell

6 GHz TEM Cell generates the Electro-Magnetic field for testing small RF devices such as wireless communication receiver, Mobile phone, etc. An external test signal applied through the input port generates a consistent and predictable TEM test field inside the cell. The radiation field from a device transmitting in the Cell can also be detected through the port using a test receiver.


The unique compact and economical design is optimized for medium accuracy measurements beyond the standard TEM Cell frequency range.

  • Receiver sensitivity testing, Transmitter radiated power testing
  • EMI and EMS tests for small Wireless devices

Features

  • Radiation and susceptibility test
  • Small size, Small footprint for desktop application
  • Specifically designed for all types of mobile phones
  • Broadband TEM Cell up to 6 GHz
  • High effective shielding
  • Able to install DUT Rotator